不銹鋼電纜橋架距地高度設(shè)為多少合適?
1, cable bridge construction, must make sure the direction, each device should be convenient maintenance, so as to avoid failure, can not repair, cause greater harm.
2、在安裝之前需要先檢查下不銹鋼電纜橋架的外觀,看下表面是不是平整光滑,不要出現(xiàn)掉漆的情況,同時(shí)看下鋼材之間的焊接是不是結(jié)實(shí)。
2, before installing, you need to check the appearance of the stainless steel cable tray, see if the surface is smooth and smooth, do not paint off, and see whether the welding between the steel is firm or not.
3、橋架的安裝不管是采用固定的還是懸掛的,都一定要看好各個(gè)部件之間連接的是不是緊固,不能有松動(dòng)的現(xiàn)象,保證施工。
3, the installation of the bridge, whether it is fixed or suspended, must be optimistic about the connection between the various components, is not tight, can not be loose phenomenon, to ensure safety in construction.
4、電纜橋架的安裝要確定好具體的位置,同時(shí)各個(gè)層之間要留距離,保證可以正常的散熱和維護(hù),同時(shí)如果有其他的管道平行著,要保證規(guī)定的距離,避免互相干擾。
4, the installation of cable tray to determine the specific location, at the same time, each layer must be left between the distance, can guarantee the normal cooling and maintenance at the same time, if there are other parallel pipeline, to ensure that the provisions of the distance, to avoid mutual interference.
熱鍍鋅的電纜橋架鍍層表面應(yīng)均勻,無(wú)過(guò)燒、掛灰、局部未鍍鋅等缺陷。靜電噴塑應(yīng)平整、光滑、均勻、不起皮,無(wú)氣泡、水泡橋架本身應(yīng)平整,無(wú)扭曲變形,內(nèi)壁應(yīng)光滑、無(wú)毛刺橋架焊縫表面應(yīng)均勻,不得有漏焊、裂紋、燒穿等缺陷。
The surface of the cable tray of hot galvanized steel wire should be even, without excessive burning, hanging dust or local galvanization. Electrostatic spray should be flat, smooth, uniform, no peeling, no bubble, blister tray itself should be smooth, without distortion, the wall should be smooth, no burr bridge weld surface should be uniform, no leakage of welding, crack, burn and other defects.
橋架水平敷設(shè)時(shí),距地高度一般不宜低于2.5m。橋架多層敷設(shè)時(shí),為了散熱、維護(hù)以及防干擾的需要,橋架層間應(yīng)留有一定的距離電纜橋架在與各種管道平行敷設(shè)時(shí),其凈距應(yīng)符合有關(guān)的規(guī)定。
When the bridge is horizontally laid, the distance from the ground should not be less than 2.5m. When the bridge is covered with multiple layers, the distance between the bridge layers should be kept a certain distance for the purpose of heat dissipation, maintenance and interference prevention. The bridge spacing shall be in line with the relevant provisions when parallel with all kinds of pipelines.
本文的精彩內(nèi)容來(lái)自山東電纜橋架詳細(xì)內(nèi)容請(qǐng)點(diǎn)擊我們的網(wǎng)站:http://qdxiaosheng.com/謝謝您的到來(lái)!
The exciting content of this article comes from the Shandong cable tray. Please click on our official website: http://qdxiaosheng.com/, thank you for coming!