托盤式電纜橋架施工安裝要點(diǎn)
托盤式電纜橋架是石油、化工、輕工、電視、電訊等方面應(yīng)用非常廣泛的一種。它具有重量輕、載荷大、造型美觀、結(jié)構(gòu)簡(jiǎn)單、安裝方便等優(yōu)點(diǎn)。它既適用于動(dòng)力電纜的安裝,也適合于控制電纜的敷設(shè)。下面山東電纜橋架公司就給大家總結(jié)一下安裝要點(diǎn),希望對(duì)大家有所幫助!
Pallet cable bridge is widely used in petroleum, chemical industry, light industry, television, telecommunications and other fields. It has the advantages of light weight, large load, beautiful shape, simple structure and convenient installation. It is not only suitable for the installation of power cable, but also suitable for the laying of control cable. Next, Shandong Cable Bridge Company will summarize the installation points for you, hoping to help you!
1、在鄰近空調(diào)水和空調(diào)風(fēng)道施工時(shí),應(yīng)注意預(yù)留出其保溫層的位置。
1. In the construction of adjacent air-conditioning water and air-conditioning duct, attention should be paid to reserving the location of its insulation layer.
2、標(biāo)準(zhǔn)層施工時(shí)應(yīng)先施工一層或一個(gè)部位,然后請(qǐng)監(jiān)理及工程有關(guān)方面檢驗(yàn)認(rèn)可后,再開始大面和施工。
2. Standard floor construction should start with one floor or one part, and then check and approve by supervisor and relevant engineering parties before large-scale construction and construction.
3、電氣豎井垂直橋架的線纜防墜落措施應(yīng)與橋架施工同步進(jìn)行。
3. Cable fall-proof measures of vertical electric shaft bridge should be carried out synchronously with bridge construction.
4、對(duì)于受污生銹的橋架,應(yīng)在穿線放電纜之前處理干凈,支架的焊接處應(yīng)及時(shí)涂刷防銹漆。
4. For the stained and rusty bridges, they should be cleaned before threading and discharging cables, and the welding parts of the supports should be painted with rust-proof paint in time.
5、敷設(shè)在豎井和不同防火分區(qū)的橋架,按設(shè)計(jì)要求位置,有防火隔堵措施。防火封堵做法為:用4mm2厚鋼板,鋼板大于橋架邊5cm,兩層鋼板封堵,兩塊鋼板中間加防火泥進(jìn)行封堵。
5. Bridges laid in shafts and different fire zones have fire prevention and blocking measures according to the design requirements. Fire-proof plugging method is: 4 mm 2 thick steel plate, steel plate larger than 5 cm bridge edge, two layers of steel plate plugging, two pieces of steel plate with fire-proof mud in the middle of the plugging.
6、出橋架的明配金屬管,需要用跨接線將橋架與明配管連接起來。
6. The open metal pipes of the bridge deck need to be connected with the open pipes by cross-connection.
7、電纜橋架及線槽敷設(shè)走向應(yīng)短捷,并應(yīng)盡量沿墻、沿柱或沿梁敷設(shè)。
7. The laying direction of cable tray and trough should be short and short, and should be laid along wall, column or beam as far as possible.
8、電纜橋架不宜與下列管道平行敷設(shè),當(dāng)無法避免時(shí),電纜橋架的位置應(yīng)符合下列規(guī)定,或采取相應(yīng)防護(hù)措施。
8. Cable bridge should not be laid parallel to the following pipelines. When it is unavoidable, the position of cable bridge should comply with the following regulations or take corresponding protective measures.
9、不同電壓、不同用途的電纜不宜敷設(shè)在同一層電纜橋架內(nèi)。
9. Cables of different voltages and different uses should not be laid in the same layer of cable bridge.
10、在工程條件下安裝或檢修不需考慮附加集中荷載時(shí),電纜梯架、托盤的工作均布荷載按電纜自重均勻分布計(jì)算。
10. When installing or repairing under engineering conditions without considering additional concentrated load, the uniform distribution load of cable ladder and pallet is calculated according to the uniform distribution of cable dead weight.
本文由山東電纜橋架友情奉獻(xiàn).更多有關(guān)的知識(shí)請(qǐng)點(diǎn)擊:http://qdxiaosheng.com!我們將用的技術(shù).真誠(chéng)的態(tài)度.為您提供為的服務(wù).更多有關(guān)的知識(shí)我們將會(huì)陸續(xù)向大家奉獻(xiàn).敬請(qǐng)期待.
This article is dedicated by the friendship of Shandong Cable Bridge Frame. For more information, please click: http://qdxiaosheng.com! We will use advanced technology and sincere attitude to provide you with comprehensive services. More relevant knowledge will be dedicated to you one after another. Please look forward to it.